Carpet and rugs reduce hotel noise in two separate ways. They soften footsteps and dropped objects at the source, which cuts impact sound travelling through the floor to the room below, and they absorb airborne sound in the room, which shortens reverberation in lobbies, corridors and restaurants. Fitted carpet over a suitable underlay does the first job far better than a loose rug, while both help with the second.
Two kinds of noise, two kinds of rating
Acoustic consultants separate hotel noise into types, and each has its own test and rating.
| Noise problem | Where it shows in a hotel | What carpet does | Common ratings |
|---|---|---|---|
| Impact sound through the floor | Footsteps, trolleys and dropped items heard in the guest room below | Cushions the impact before it enters the structure | ΔLw under ISO 10140-3 and ISO 717-2 in Europe. IIC under ASTM E492 and E989 in North America |
| Airborne sound within a space | Echo and build up of voices in lobbies, restaurants and long corridors | Absorbs part of the sound energy that reaches the floor | Absorption coefficients and αw under ISO 354 and ISO 11654. NRC under ASTM C423 |
| Airborne sound between rooms | Voices and televisions through walls and floors | Contributes little. This depends on the wall and floor build up | STC and Rw for the construction, not the carpet |
Understanding which problem a project has is the first step. A rug in a guest room does little for noise in the room below if most of the floor around it is bare timber.
Impact sound: where carpet matters most
Guests notice footsteps from the room above more than almost any other noise. On a hard floor, the energy of each step passes straight into the slab. A soft, resilient covering absorbs part of that energy at the surface.
In Europe the reduction a floor covering gives is measured in a laboratory by placing it on a standard concrete floor, running a tapping machine on it and comparing the sound in the room below with and without the covering. The weighted result, ΔLw, is the improvement in decibels. In North America, impact performance of a floor and ceiling assembly is rated as IIC, impact insulation class, and the carpet is tested as part of that assembly.
The International Building Code sets a minimum IIC of 50, or 45 if field tested, for floor and ceiling assemblies separating dwelling units and sleeping units, which include hotel rooms, from each other and from public areas. The section number has changed between editions, so check the edition adopted locally. Many hotel brands set their own higher targets. The acoustic consultant decides how the floor build up, ceiling and covering together achieve the figure.
For specification this means:
- Fitted carpet with a suitable underlay usually gives a large improvement in impact sound. Loose rugs only help where they are, and leave the bare floor around them untreated.
- The underlay often contributes as much as the carpet. Specify them together and test them together.
- Where hard floors are chosen for guest rooms, an acoustic underlayer below the hard floor is needed, and rugs become a comfort feature rather than the acoustic solution.
Airborne sound: reverberation in public areas
Hotel lobbies are often built from stone, glass and plaster, all of which reflect sound. Voices, footsteps and music build up into a general noise that makes conversation tiring. Soft surfaces absorb part of the sound that reaches them and shorten the reverberation time.
Carpet and rugs are most effective at absorbing middle and higher frequencies, which include much of the energy in speech. Thicker, denser pile and an underlay generally increase absorption. A large rug in a stone lobby can make a noticeable difference to how the space feels, but it is one surface among many, and ceilings and walls usually carry most of the acoustic treatment.
Absorption is measured in a reverberation room and reported as coefficients across frequencies, or as a single number: αw under ISO 11654, or NRC under ASTM C423.
Corridors
Corridors combine both problems: impact sound to the rooms below and around, and reverberation along a long hard space. Luggage wheels and housekeeping trolleys add rolling noise. Low, dense, fitted carpet over a firm underlay addresses all three, and is also the construction that suits wheelchair access and corridor fire requirements. This is one reason corridors are almost always carpeted in hotels.
Choices that affect acoustic performance
| Choice | Effect on impact sound | Effect on absorption |
|---|---|---|
| Fitted carpet versus loose rug | Fitted carpet treats the whole floor | Both absorb where they lie |
| Underlay | Usually a large contribution | Adds absorption |
| Pile height and density | Higher, denser pile tends to help | Thicker pile tends to absorb more |
| Fibre | Wool and synthetics both work. Construction matters more than fibre | Similar |
| Rug size relative to the room | Larger coverage helps | Larger coverage helps |
Each of these trades against other requirements. A higher pile helps acoustics but works against wheelchair access and some fire classes. A soft underlay helps impact sound but must stay firm enough for accessible routes. The acoustic consultant, fire consultant and designer need to agree one construction for each area.
Specifying for sound
- Ask the acoustic consultant for the impact and reverberation targets for each area.
- Specify carpet and underlay as a system and ask for tests of the combination.
- State whether laboratory or field results are needed.
- Use rugs to improve comfort and absorption in public areas, not as the main impact sound measure in guest rooms with hard floors.
- Record the underlay in the attic stock plan, because replacing carpet with a different underlay can change the result.
How Eastern Mills supports acoustic specifications
Eastern Mills makes broadloom for corridors and guest rooms and hand tufted, hand knotted and handloom rugs for public areas, from its site in Bhadohi. Pile height, density and construction are set per project, and testing to the standards the acoustic consultant names is arranged per order. See our contract carpets page and the hospitality overview.
Frequently asked questions
Does a rug stop footstep noise reaching the room below?
Only where it lies. For a measurable improvement across a guest room, fitted carpet with an underlay, or an acoustic layer under a hard floor, is needed.
Is NRC the right rating for carpet?
NRC describes absorption within a room. For noise to the room below, the relevant ratings are impact ratings such as IIC or ΔLw.
Does wool absorb sound better than nylon?
Construction, pile height, density and underlay matter more than fibre for acoustics.
Who sets the acoustic targets?
The acoustic consultant, guided by the building code and the hotel brand standard.